Leading Manufacturer of scineers combined refrigerator and freezer 2-8 degree c & -25 degree c and scineers combined refrigerator and freezer 2-8 degree c & -40 degree c from Dombivli.

Scineers Combined Refrigerator And Freezer 2-8 Degree C & -25 Degree C

Scineers Combined Refrigerator And Freezer 2-8 Degree C & -25 Degree C
  • Scineers Combined Refrigerator And Freezer 2-8 Degree C & -25 Degree C
  • Scineers Combined Refrigerator And Freezer 2-8 Degree C & -25 Degree C
  • Scineers Combined Refrigerator And Freezer 2-8 Degree C & -25 Degree C
Get Best Quote
Approx. Price: Rs 1,15,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
BrandScineers
ControllerMicroprocessor
Temperature sensor2 separate cooling systems (2 compressors)
RefrigerantCFC Free. R600a
DisplayDigital
AlarmYes
LockYes
In built DataloggerYes
Voltage220V
Frequency50Hz
Back up batteryYes. 72 hours back-up battery for display and alarms system during power failure.

High-precision Temperature Control
• High-precision microcomputer temperature control system.• Multiple alarm sensors for High and low temperature, ambient temperature and evaporator temperature ensuring safe and stable running.• High brightness digital temperature display with 1°C display precision.
Refrigeration System• Equipped with high-efficiency compressor and fan for energy saving and silent running.• 2 separate cooling systems (2 compressors): one ensuring temperature from 2°C-8°C for the upper chamber, the other one keeping the temperature from -10°C to -40°C settable for the down chamber. If one compressor is damaged, the other one could still work normally.
Security System• Audible and visual alarm system: High and low temperature alarm, high ambient alarm, sensor failure alarm, door opening alarm, power failure alarm, low battery alarm, data-logger failure alarm• External door handle and padlock to prevent unauthorized opening• 72 hours back-up battery for display and alarms system during power failure
Human-oriented Design• Drawers for convenient sample storage• Shelves with divided sections• Door gasket surrounded with hot gas pipe for better defrosting• With built-in USB data-logger for temperature data storage more than 600 days
Request
Callback
Yes! I am Interested

Scineers Combined Refrigerator And Freezer 2-8 Degree C & -40 Degree C

Scineers Combined Refrigerator And Freezer 2-8 Degree C & -40 Degree C
  • Scineers Combined Refrigerator And Freezer 2-8 Degree C & -40 Degree C
  • Scineers Combined Refrigerator And Freezer 2-8 Degree C & -40 Degree C
  • Scineers Combined Refrigerator And Freezer 2-8 Degree C & -40 Degree C
Get Best Quote
Approx. Price: Rs 1,15,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
BrandScineers
ControllerMicroprocessor
Temperature sensor2 separate cooling systems (2 compressors)
RefrigerantCFC Free. R600a
DisplayDigital
AlarmYes
LockYes
In built DataloggerYes
Voltage220V
Frequency50Hz
Back up batteryYes. 72 hours back-up battery for display and alarms system during power failure.

High-precision Temperature Control
• High-precision microcomputer temperature control system.
• Multiple alarm sensors for High and low temperature, ambient temperature and evaporator temperature ensuring safe and stable running.
• High brightness digital temperature display with 1°C display precision.

Refrigeration System
• Equipped with high-efficiency compressor and fan for energy saving and silent running.
• 2 separate cooling systems (2 compressors): one ensuring temperature from 2°C-8°C for the upper chamber, the other one keeping the temperature from -10°C to -40°C settable for the down chamber. If one compressor is damaged, the other one could still work normally.

Security System
• Audible and visual alarm system: High and low temperature alarm, high ambient alarm, sensor failure alarm, door opening alarm, power failure alarm, low battery alarm, data-logger failure alarm
• External door handle and padlock to prevent unauthorized opening
• 72 hours back-up battery for display and alarms system during power failure

Human-oriented Design
• Drawers for convenient sample storage
• Shelves with divided sections
• Door gasket surrounded with hot gas pipe for better defrosting
• With built-in USB data-logger for temperature data storage more than 600 days
Request
Callback
Yes! I am Interested
X

Explore More Products

View All Products
Tell Us What Are You Looking For ?




Reach Us
K.Golani (Managing Director)
Scineers Scientific India Private Limited
Flat No 101, Daisy Building No 08, Regency Estate, Kalyan Shil Road, Dnyaneshwar Nagar , Dombivli, East
Dombivli - 421201, Thane, Maharashtra, India
Get Directions

Call Us


Send E-mail